Run a house’s cold and hot water in the free 2D/3D editor in PEX, trunk and branch: a three-quarter-inch main for each, and half-inch branches to the fixtures through reducing tees and elbows, with a cap at the end of each main. The list counts the PEX in feet for each size and the fittings one by one. No sign-up.
No sign-up needed to try
Press Run the water lines and the editor opens. Start from a house that already stands, your own or a gallery house opened as your own copy. Put the water heater’s rough-in and the water service entry down from the catalog, then run the cold main from the service entry, one piece at a time, each set in place by the position typed on its card.
The cold water runs as a main of three-quarter-inch PEX, and so does the hot. Where a fixture takes its water, a reducing tee steps the main down to a half-inch branch, and elbows carry the branch to the fixture. A cap closes the end of a main.
The film runs the cold to the bathtub, the washer, the toilet, the kitchen sink and the lavatory, then the hot main from the water heater to the bathtub, the washer, the kitchen sink and the lavatory: sixty pieces with the water heater and the service entry, each placed by hand.
Isolate Water supply, PEX in the scene to see the lines on their own, then turn the house around them in the 3D view.
Press Calculate. The PEX is counted in feet for each size, three-quarter inch and half inch; the tees, reducing tees, elbows and caps are counted one by one.
Open a gallery house as your own copy where its author allows it, and run its cold and hot water through the house.
There is no download and no account. What you draw is kept in this browser and comes back after a reload; nothing is backed up beyond it, the browser holds a single drawing, and you can download it as a file with Export JSON in the File menu.
A water line run by hand, pipe and fitting, is counted free. On a subscription, builders also get automatic layout of the roof and the networks, and parts set in place together with one press. See pricing.
Three-quarter-inch PEX for the cold and hot mains, half-inch for the branches, with a reducing tee between them. Each pipe and fitting carries its size on its card.
Yes. Each is a main with branches of its own, run to the fixtures that take it.
Yes. Put the water heater’s rough-in down first and run the hot main from it.
Each tee, reducing tee, elbow and cap is counted one by one, and the PEX in feet for each size.
It opens in the phone’s browser; a mouse is quicker for assembling a run.